Ammonia Emission Control System – Louisiana

Featured Project: Ammonia Vapor Control at CF Industries – LDEQ ESL & EPA BACT Compliance (Case Study)

At an ammonia production facility in Ascension Parish, Louisiana, producing nearly 8 million tons of nitrogen products annually — ammonia emissions from storage tanks, loading operations, and process vents pose significant odor and health risks near residential areas. Under LDEQ 30 TAC §101.20: Toxic Air Contaminants, ammonia has ESLs of 0.14 mg/m³ (acute odor) and 1.3 mg/m³ (chronic), requiring BACT for exceedances or nuisances. For anhydrous ammonia storage, 30 TAC §106.477: Anhydrous Ammonia Storage PBR allows operations without atmospheric venting if emissions <25 tpy VOC equivalents. Envent’s recirculating wet scrubbers integrate these controls, ensuring odor-free operations and zero NOVs, as demonstrated in our support for the complex’s decarbonization efforts, including CO2 capture for blue ammonia production.

The Challenge: Ammonia Vapor Emissions from Ammonia Storage & Venting

The Donaldsonville Complex, with its six ammonia plants and extensive pipeline/rail/barge shipping, generates ammonia vapors during filling, venting, and maintenance—exceeding LDEQ’s ESL-odor threshold and risking public complaints in nearby communities.

Key Risks:

  • Odor & Health Hazards: Ammonia at >50 ppm causes eye/respiratory irritation; uncontrolled venting triggers §101.20 investigations for effects screening.
  • Regulatory Pressure: Facilities must demonstrate compliance via dispersion modeling (e.g., SCREEN3 per LDEQ guidelines); exceedances incur $10,000–$100,000/day fines under La. R.S. 30:2050.3, plus EPA NESHAP reporting for HAPs.
  • Operational Constraints: Previous carbon-only systems saturated quickly, requiring frequent change-outs and halting production amid §106.477 PBR limits on emissions.

Envent’s Solution: EVAC-3000 Recirculating Wet Scrubber for Ammonia Capture

Envent secured a LDEQ minor source authorization under §106.4 and deployed the EVAC-3000—a 3,000 CFM mobile wet scrubber optimized for ammonia streams, routing tank vents via vapor recovery lines.

Treatment Process:

  • Ammonia Absorption: Two-stage packed tower with alkaline media (caustic soda solution, pH 10–11) achieved >99% removal efficiency (inlet 5,000+ ppm → outlet <10 ppm), per EPA BACT for chemical manufacturing vents—converting NH3 to ammonium salts for safe disposal. Automated pH/ORP sensors and media recirculation prevented breakthrough.
  • Polishing & Safety: Integrated mist eliminator and HEPA filter for <1 ppm stack emissions; real-time monitoring (NH3 analyzers, flow meters) ensured §101.20 ESL compliance without atmospheric release.
  • Integration: Tied into plant SCADA for automated shutdowns; handled variable flows during filling (up to 500 gpm).

System operated continuously for 4 weeks with 99% uptime. For ammonia-specific setups, explore Envent’s wet scrubber rentals.

Official Resources:

Proven Benefits: Odor Elimination, Compliance, & $50K+ Savings

Envent’s scrubber turned a high-risk operation into a compliant success, outperforming alternatives:

Benefit Project Impact
Ammonia Removal Efficiency >99% — inlet 5K+ ppm → outlet <10 ppm, meeting §101.20 ESLs & EPA BACT.
Media Life Extension >40 days vs. carbon’s <5 days — aligned with §106.477 PBR limits.
Cost Savings $50,000+ vs. carbon-only (fewer swaps, no disposal fees).
Compliance Assurance Zero odors/NOVs; full modeling records for LDEQ audits.
Uptime & Safety 99% availability; <1 ppm stack NH3 protected workers/communities.

This Donaldsonville project highlights Envent’s expertise in LDEQ ammonia vapor controls, where BACT prevents enforcement risks amid the complex’s blue ammonia expansion.

Request a Quote in 30 seconds here or contact us at 888-997-9465. You can also send us an email inquiry at [email protected]